Dedicated remodel housing for use in Non-IC or insulated ceilings, must specify. Air-tight construction provides energy savings by reducing the flow of air through the ceiling.
SPECIFICATIONS :
CONSTRUCTIONHousing: 0.040 aluminum housing adjusts to a maximum ceiling thickness of 5/8” (16mm). Housing terminates at a 1/4” ceiling flange for even positioning of housing angle within the ceiling. Structural arm consists of 0.050 steel and connects to housing with j-box and ballast. Integral springs brackets provided.
Air Flow Restriction: Housing has factory installed gaskets to restrict airflow from room into ceiling plenum to <2CFM (cubic feet per minute) in accordance with ASTM-283 Air-Tight requirements.
Mounting: Four high tension tempered steel springs secure remodel housing to 5/8” thick (max) ceiling (Hole cutout template provided for convenience).
Junction Box: Prewired 25 cubic inch 0.064” thick galvanized steel, with five 1/2”, two 3/4” knockouts, four Romex® pryouts, and snap on covers. All leads are 18AWG wire, the ground wire is connected to the bottom, and quick connectors are supplied on all leads. Through branch circuit wiring, (4-in, 4-out).
CLEARANCE
Non-IC: Non-Insulated housings require a minimum clearance of 3” from thermal insulation and 1/2” from adjacent building components.
IC: Insulated ceiling housings are direct contact rated; no minimum clearance is required.
ELECTRICAL
Input Voltage: 120V or 120-277V
Lumens / Wattage: NHRMIC2-509 = 900lm / 15W; NHRM2-515 = 1500lm / 18W; NHRM2-525 = 2500lm / 30W
Operating Temp.: 0˚C to 45˚C ambient temperature
Dimming: Triac, ELV or 0-10V dimming
Emergency: Housing can be specified with connections for emergency battery installation. Requires top access. Must specify battery with remote test switch separately, NEPK-BSL17C-C2U.
LABELS AND LISTINGS
cULus Listed for Damp Location w/ Feed Through (Wet Location when used with compatible reflector)
5-Year Limited Warranty
Meets or exceeds ASTM-283 Air-Tight Requirements
Emergency LED Driver meets Title 20 CEC efficiency standards