Lutron Vive Wireless 20A Receptacle With Clear Connect Technology Control
CAR2S-20-STR
Lutron Vive Wireless 20A Receptacle
Please call us at 877-487-4444 to purchase this product or email us at buyriteelectric@gmail.com
The Wireless Receptacle is a radio-frequency (RF) receptacle switching solution that is capable of controlling 15 A or 20 A split or duplex style receptacles when paired with Pico wireless controls and Radio Powr Savr occupancy/vacancy sensors.
Communication with RF input devices, such as Pico wireless controls and/or Radio Powr Savr occupancy / vacancy sensors, is accomplished using Lutron Clear Connect RF Technology.
These products are compatible with the Vive wireless hub which enables a simple setup process using a standard web browser on any Wi-Fi enabled phone, tablet, or computer. The hub enables control and monitoring of all Vive devices. The Vive wireless hub can be added at any time. For a complete list of features supported with the Vive wireless hub, see specification submittal 369902.
LUTRON VIVE FEATURES:
Utilizes Lutron Clear Connect RF Technology
Receives wireless inputs from up to 10 Pico wireless controls and 10 Radio Powr Savr occupancy / vacancy sensors
Capable of switching general-purpose loads
Capable of switching downstream receptacles
Adaptive Switching: maximizes relay life by switching at the point of minimum energy on the AC power curve Tamper resistant
RoHS Compliant
Includes required controlled outlet labels for code compliance
Includes plastic screw terminal covers
LUTRON VIVE SPECIFICATIONS:
CULUs 498B-SA; Listed with Federal Specification WC596
FCC approved. Complies with the limits for a Class B device, pursuant to Part 15 of the FCC
Industry Canada
NOM and IFT (Mexico)
ASHRAE 90.1 compliant when used with wireless transmitters or the Vive wireless hub
CEC Title 24 compliant when used with wireless transmitters or the Vive wireless hub
NEMA® WD-6 compliant
120 V~ 50 / 60 Hz
System Communication
Operates using Clear Connect RF Technology for reliable wireless communication.
RF range is 60 ft (18 m) line of sight, or 30 ft (9 m), through walls. For maximum RF range do not place large office furniture in front of wireless receptacles.
Ambient operating temperature: 32 ˚F to 122 ˚F (0 ˚C to 50 ˚C)
0% to 90% humidity, non-condensing
For indoor use only
Each terminal accepts up to two 14 AWG to 12 AWG (1.5 mm2 to 4.0 mm2) wires
Side or back wire installation capable
Solid or stranded wires
Copper wires only
Lutron Vive Wireless Specs
Regulatory Approvals
• cULus 498B-SA; Listed with Federal Specification WC596
• FCC approved. Complies with the limits for a Class B device, pursuant to Part 15 of the FCC
• Industry Canada
• NOM and IFT (Mexico)
• ASHRAE 90.1 compliant when used with wireless transmitters or the Vive wireless hub
• CEC Title 24 compliant when used with wireless transmitters or the Vive wireless hub
• NEMA® WD-6 compliant Power
• Operating voltage: 120 V~ 50 / 60 Hz System Communication
• Operates using Clear Connect RF Technology for reliable wireless communication.
• RF range is 60 ft (18 m) line of sight, or 30 ft (9 m), through walls. For maximum RF range do not place large office furniture in front of wireless receptacles. Environment
• Ambient operating temperature: 32 ˚F to 122 ˚F (0 ˚C to 50 ˚C) • 0% to 90% humidity, non-condensing
• For indoor use only Terminals
• Each terminal accepts up to two 14 AWG to 12 AWG (1.5 mm2 to 4.0 mm2 ) wires
• Side or back wire installation capable
• Solid or stranded wires
• Copper wires only Switching
• Adaptive zero cross—maximizes relay life by actively adapting to variations in relay timing to switch at the point of minimum energy on the AC power curve. Load
• Available in 15 A or 20 A varieties. See chart below for maximum load ratings. • No minimum load requirements.
• The Wireless Receptacle may be used with, but is not limited to, the following: – Monitors
– Fans
– Humidifiers
Note: Refer to the manufacturer’s guidelines for acceptable switching methods.
• The Wireless Receptacle is NOT suitable for use with devices that require any of the following:
– Shut-down process before power is interrupted, such as computers.
– Cool-down process before power is interrupted, such as projectors. – Programming, such as clocks or DVRs.
– Long warm-up cycle.
• Ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls.
• Not for use with loads that present a hazard if automatically energized. For example, heaters.
• Any receptacles that are controlled by an automatic control device must be marked with “ u” located on the controlled receptacle outlet where visible after installation as stated in 2014 NECR Article 406.3(E).
NOTE: Labels with this marking “u” are included with the product.
Mounting • Typical U.S. style wallbox dimensions: 3.0 in (76 mm) H x 2.0 in (51 mm) W x 2.5 in (64 mm) D Load Type Relay Ratings 120 V~ 15 A single phase only CAR2S-15-STR, CAR2S-15-DTR 120 V~ 20 A single phase only CAR2S-20-STR, CAR2S-20-DTR Tungsten 1000 W 1500 W LED/CFL 3.75 A 5 A AC General Use 15 A 20 A Resistive 15 A 20 A Inductive 15 A 20 A Motor 0.5 HP 120 V~ 1.0 HP 120 V~