Utopia Lighting LAD8A 8” Architectural New Construction Frame,4000K

2 sold in last 8 hours

LAD8A(C)-16L/xx-UNV-DM-WW/CW/PLW-Oxx

$251.76
$264.36
customers are viewing this product
8” Horizontal architectural frame-in is design for high quality application with lens. Ideal for commercial, retail, conference rooms and hospital where architectural LED downlight fixture is required.

FEATURES:

Heavy gauge die formed galvanized steel mounting frame trim clips to mount open conical shape reflector.
Vertically adjustable mounting brackets that use 16-gauge flat bar hangers, conduit or C channel. Provides 3-3/4” total adjustment.
C channel is optional, not included as std.
Post installation adjustment possible from above or below the ceiling.
Maximum 1-1/2” ceiling thickness.
Reflectors are optically designed to maximize lumen output and to provide superior glare control.
Non-insulated ceilings or where insulation can be kept 3” from all side of housing.

SPECIFICATIONS:

JUNCTION BOX:

Galvanized steel junction box with seven 1/2” knockouts, four pryouts, and snap on cover.
Electrical connections are made through a single junction box door.

LED

CREE LED technology.
50,000 hours.
4000K color temperature standard.
16W, 25W, 38W, 50W LED.
Color Rendering Index: > 90

ELECTRICAL

Input voltage: 120-277V
3 in 1 dimming: Triac (120V only), 0-10V (dim to 1%, 120-277V), ELV (120V only).
Thermal protection.
Surge protection (3kV line to line, 6kV line to earth).
Protections: Output open load, over-current and short-circuit(hiccup), and over-temperature with auto recovery.
Conducted and radiated EMI: Compliant with FCC CFR Title 47 Part 15 Class B (120 Vac)/ Class A (277 Vac) and EN55015 (CISPR 15) at 220/230/240 Vac.
<ELCU-200>
Guarantees emergency lighting remains ON or is turned on when power to the control device is lost.
Interfaces with fire alarm panel or security system.
“Watchdog” feature allows emergency loads to be controlled in tandem with normal power loads.
UL listed for use in emergency circuits.

ELCU-200
Guarantees emergency lighting remains ON or is turned on when power to the control device is lost.
Interfaces with fire alarm panel or security system.
“Watchdog” feature allows emergency loads to be controlled in tandem with normal power loads.
UL listed for use in emergency circuits

LISTING

UL/CUL listed for damp locations with covered ceiling.
UL/CUL wet location listed.
Listed to UL 1598 and UL 8750.
Minimum 75°C supply conductors.
CSA certified to US.
Energy Star certified.
5 years limited warranty.
ARRA compliant (optional).
Please email us with the products you need and the details of your job at buyriteelectric@gmail.com